K00017 STACKING KIT  
Installation Instructions  
1. The K00017 stacking kit is used for stacking an E-0400  
on an E-0600 ice machine. The bin must be leveled  
before proceeding. NOTE: THIS STACKING KIT IS  
ALSO USED, WHEN STACKING G-0600 ON G-0800  
ICE MACHINES.  
4. INSTALLATION OF WATER SHIELD:  
A. Remove angle “A”, the water pump, float valve  
bracket assembly, and sump trough from top ice  
machine.  
2. INSTALLATION OF E-0600 ICE MACHINE:  
A. See service manual for uncrating and inspection of  
ice machine.  
B. Remove existing sheet metal screw at lower right  
corner of bulkhead below siphon tube. Locate water  
shield above the lower machine’s electrical box. Use  
existing screw to fasten flange of shield to bulkhead.  
Apply RTV sealant to the top edges of flange to  
provide a watertight seal.  
B. Remove top cover from ice machine (NOTE: do not  
put screws back in.).  
C. Set ice machine carefully and squarely on bin.  
D. Position shim angle, provided in kit, on right side, as  
shown in Illustration 1.  
C. Reinstall the sump trough, float valve bracket  
assembly, and water pump.  
E. Add foam tape, as shown in Illustration 1.  
F. With four screws, install top cover from kit on left  
side of ice machine (NOTE: flange goes over side  
panel.).  
5. INSTALLATION OF ICE CHUTE:  
A. Remove the ice chute from kit and set bottom  
mounting brackets over angle “B” on E-0600 ice  
machine (Illustration 3).  
G. Remove right-hand side panel.  
3. INSTALLATION OF E-0400 ICE MACHINE:  
A. See service manual for uncrating and inspection of  
ice machine.  
B. Put angle “A” in slots of top mounting brackets and  
secure in place.  
B. Remove right-hand side panel and bottom four  
screws on left-hand side panel.  
C. Set E-0400 ice machine on E-0600 ice machine with  
right-hand sides in line (NOTE: flange on top cover  
should be inside left-hand side panel.).  
C. Check for free movement of water curtains.  
D. Proceed to ice machine service manuals for electrical  
and water hook-up and start-up procedure.  
D. Install four screws in bottom left-hand side panel.  
E. Bolt right-hand sides of ice machines together with  
1/4-20 x 5/8” long bolt, lock washer, and nut,  
provided in kit.  
F. Reattach right-hand side panels.  
Manitowoc Ice, Inc.  
2110 South 26 Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA  
Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879  
8001403  
Rev. 05/11/01  
 

KWC Indoor Furnishings S10D802 User Manual
Lenovo Switch H415 User Manual
LG Electronics Microwave Oven LMVM1935SB User Manual
Lightolier Indoor Furnishings SW STRIP User Manual
Linear Safety Gate DRG User Manual
Magnavox Flat Panel Television 26MF605W Series User Manual
Makita Sander BO5030 User Manual
Maytag Washer MAH2400AWW User Manual
Metra Electronics Car Stereo System 99 7013 User Manual
Metra Electronics Car Stereo System 99 7316 User Manual